8.24.1. Hydraulic modulator and electronic control device

Removal

PERFORMANCE ORDER
1. Remove the accumulator.
2. Remove the relay block from the hydraulic modulator.
3. Uncover a tank of brake fluid and, using the syringe, pump out all liquid from a tank.
4. Disconnect the electric socket from the top part of the hydraulic modulator.
5. Purify dirt of junctions of brake tubes to the main brake cylinder. Enclose rags under places of connections to collect the flowed-out brake fluid. Unscrew nuts of fastening of brake tubes to the main brake cylinder.
6. Unscrew three bolts and remove the hydraulic modulator and the control unit from a motor compartment up.

Installation

PERFORMANCE ORDER

Installation is made in the sequence, the return to removal, but at the same time it is necessary to remove air from the brake system.